MegaMix Emerald is a one-step dye-based RT-qPCR kit for sensitive detection and quantification of RNA targets. It combines reverse transcription and real-time PCR in a single reaction and uses Microzone's microGREEN fluorescent dsDNA intercalating dye for amplification detection through the FAM/SYBR channel.
The kit contains Hot Start Taq DNA polymerase, dUTP and thermolabile UNG for carryover-contamination control, plus a concentrated reverse-transcriptase/RNase-inhibitor enzyme mix. It is suitable for total RNA, mRNA and viral RNA, including low-copy targets, and can be used for gene-expression analysis, pathogen-detection research, melt-curve analysis and High-Resolution Melting.
Compatible Sample Types:
This kit is compatible with the following sample types:
- mRNA
- total RNA
- viral RNA
- low-copy RNA
ย What is microGREEN?
microGREEN is Microzone's fluorescent double-stranded-DNA intercalating dye for qPCR.
During amplification, microGREEN binds newly generated double-stranded DNA and produces a fluorescence signal that increases with PCR-product accumulation.
Contamination Control:
*dUTP + thermolabile UNG โ carryover amplicon degradation โ reduced contamination risk
UNG is active at room temperature and is irreversibly inactivated at 95ยฐC
Instrument Compatibility
MegaMix Emerald RT-qPCR is compatible with real-time PCR instruments capable of detecting fluorescence in the FAM/SYBR channel.
Microzone offers No ROX / Lo-ROX / Hi-ROX formulations.
- One-step reverse transcription and qPCR
- microGREEN third-generation dsDNA-intercalating dye
- Hot Start Taq DNA polymerase
- Designed for low-copy RNA targets
- Single-copy detection stated in Microzone’s datasheet
- Thermolabile UNG + dUTP carryover-contamination control
- Standard and fast cycling compatibility
- Compatible with GC- and AT-rich targets
- Suitable for inhibitor-containing/direct-to-PCR workflows where validated
- Suitable for mRNA, total RNA and viral RNA
- Gene-expression analysis
- Pathogen-detection research
- Melt-curve analysis
- High Resolution Melting
- No-ROX, Lo-ROX and Hi-ROX formats
- Detection through the FAM/SYBR channel
- Ready-to-use 2X mastermix format
- Quantification of total RNA
- mRNA quantification
- Viral RNA analysis
- Low-copy RNA targets
- Gene-expression studies
- Pathogen-detection research
- Dye-based one-step RT-qPCR
- Melt-curve analysis
- High Resolution Melting
- GC-rich targets
- AT-rich targets
- Laboratories requiring fast cycling
- Workflows where PCR carryover control
- Direct-to-PCR workflows validated with compatible sample-preparation products
- Laboratories requiring No-ROX, Lo-ROX or Hi-ROX formulations
- Product name: MegaMix Emerald RT-qPCR Kit
- Brand: Microzone
- SKU: 2MME-RTU
-
UNSPSC Code: 41106300
- Product description: A fast, readyโtoโuse mix combining reverse transcription and qPCR in one tube, powered by microGREEN dye, Hot Start Taq, and UNG/dUTP for clean curves, high specificity, and contamination control.
- Price: From ยฃ101
- Availability: same day shipping on orders before noon
- Detection method: Dye-based qPCR
- Fluorescent dye: microGREEN
- Polymerase: Hot Start Taq
- Reverse Transcriptase: Included
- Format: 2X mastermix
- ROX options: NO ROX / Low ROX / High ROX
- UNG: Optional
- RNase inhibitors: Included
- dUTP: Available with UNG
- HRM: Supported
- Melt curve analysis: Supported
- Fast cycling: Supported
- Low-copy detection: Single-copy claim
- Instrument compatibility: FAM/SYBR channel
What is MegaMix Emerald Dye RT-qPCR Kit?
Answer: MegaMix Emerald is a one-step dye-based RT-qPCR kit designed to reverse-transcribe and quantify RNA in a single reaction using Microzone’s microGREEN fluorescent intercalating dye.
What types of RNA can MegaMix Emerald be used with?
Answer: Microzone lists mRNA, total RNA and viral RNA as suitable template types.
Can MegaMix Emerald be used for low-copy RNA?
Answer: Yes. The kit is specifically described as optimised for low-copy RNA targets.
What is microGREEN?
Answer: microGREEN is Microzone’s fluorescent double-stranded-DNA intercalating dye used to detect amplified DNA during real-time PCR.
Is microGREEN detected using the SYBR channel?
Answer: Yes. Microzone’s datasheet states that fluorescence acquisition can be performed using a compatible FAM/SYBR channel.
Can MegaMix Emerald be used for gene-expression analysis?
Answer: Yes. Gene-expression analysis is an explicitly listed application.
Can MegaMix Emerald be used with viral RNA?
Answer: Yes. Viral RNA is one of the RNA template types listed by Microzone.
Can MegaMix Emerald be used for pathogen detection?
Answer: Yes. Pathogen detection is listed as an application. The product remains Research Use Only.
Does MegaMix Emerald contain a hot-start polymerase?
Answer: Yes. It contains chemically modified Hot Start Taq DNA polymerase that is activated during heating to 95ยฐC.
Does MegaMix Emerald include UNG?
Answer: Yes. The current one-step formulation includes thermolabile UNG.
Does MegaMix Emerald contain dUTP?
Answer: Yes. dUTP is included as part of the carryover-contamination-control system.
How does UNG help prevent PCR carryover contamination?
Answer: UNG acts on uracil-containing products from earlier PCR reactions before amplification starts, reducing the chance that carryover amplicons will generate false amplification.
Can MegaMix Emerald be used for melt-curve analysis?
Answer: Yes. Melt-curve analysis is explicitly listed as a use for MegaMix Emerald.
Can MegaMix Emerald be used for High Resolution Melting?
Answer: Yes. Microzone specifically identifies HRM as an application.
Does MegaMix Emerald support fast cycling?
Answer: Yes. Its datasheet states that it is compatible with standard and fast cycling conditions.
Can MegaMix Emerald be used with GC-rich targets?
Answer: Microzone’s datasheet states compatibility with GC-rich and AT-rich templates.
Is MegaMix Emerald inhibitor resistant?
Answer: Microzone describes the product as inhibitor-resistant and identifies direct-to-PCR use with products such as microLYSIS-RNA as an application.
What reaction volume should I use?
Answer: The current datasheet provides a standard 20 ยตl reaction.
Which ROX formulation should I choose?
Answer: MegaMix Emerald is available in No-ROX, Lo-ROX and Hi-ROX formats. Selection should depend on the reference-dye requirements of the qPCR instrument.
Why choose MegaMix Emerald for one-step RT-qPCR?
Answer: Choose MegaMix Emerald when you require dye-based RNA quantification with one-step reverse transcription, Hot Start Taq, microGREEN detection, low-copy-target capability, HRM support and built-in dUTP/UNG carryover control.
ย
- One-step reverse transcription and qPCR
- microGREEN third-generation dsDNA-intercalating dye
- Hot Start Taq DNA polymerase
- Designed for low-copy RNA targets
- Single-copy detection stated in Microzone’s datasheet
- Thermolabile UNG + dUTP carryover-contamination control
- Standard and fast cycling compatibility
- Compatible with GC- and AT-rich targets
- Suitable for inhibitor-containing/direct-to-PCR workflows where validated
- Suitable for mRNA, total RNA and viral RNA
- Gene-expression analysis
- Pathogen-detection research
- Melt-curve analysis
- High Resolution Melting
- No-ROX, Lo-ROX and Hi-ROX formats
- Detection through the FAM/SYBR channel
- Ready-to-use 2X mastermix format
- Quantification of total RNA
- mRNA quantification
- Viral RNA analysis
- Low-copy RNA targets
- Gene-expression studies
- Pathogen-detection research
- Dye-based one-step RT-qPCR
- Melt-curve analysis
- High Resolution Melting
- GC-rich targets
- AT-rich targets
- Laboratories requiring fast cycling
- Workflows where PCR carryover control
- Direct-to-PCR workflows validated with compatible sample-preparation products
- Laboratories requiring No-ROX, Lo-ROX or Hi-ROX formulations
- Product name: MegaMix Emerald RT-qPCR Kit
- Brand: Microzone
- SKU: 2MME-RTU
-
UNSPSC Code: 41106300
- Product description: A fast, readyโtoโuse mix combining reverse transcription and qPCR in one tube, powered by microGREEN dye, Hot Start Taq, and UNG/dUTP for clean curves, high specificity, and contamination control.
- Price: From ยฃ101
- Availability: same day shipping on orders before noon
- Detection method: Dye-based qPCR
- Fluorescent dye: microGREEN
- Polymerase: Hot Start Taq
- Reverse Transcriptase: Included
- Format: 2X mastermix
- ROX options: NO ROX / Low ROX / High ROX
- UNG: Optional
- RNase inhibitors: Included
- dUTP: Available with UNG
- HRM: Supported
- Melt curve analysis: Supported
- Fast cycling: Supported
- Low-copy detection: Single-copy claim
- Instrument compatibility: FAM/SYBR channel
What is MegaMix Emerald Dye RT-qPCR Kit?
Answer: MegaMix Emerald is a one-step dye-based RT-qPCR kit designed to reverse-transcribe and quantify RNA in a single reaction using Microzone’s microGREEN fluorescent intercalating dye.
What types of RNA can MegaMix Emerald be used with?
Answer: Microzone lists mRNA, total RNA and viral RNA as suitable template types.
Can MegaMix Emerald be used for low-copy RNA?
Answer: Yes. The kit is specifically described as optimised for low-copy RNA targets.
What is microGREEN?
Answer: microGREEN is Microzone’s fluorescent double-stranded-DNA intercalating dye used to detect amplified DNA during real-time PCR.
Is microGREEN detected using the SYBR channel?
Answer: Yes. Microzone’s datasheet states that fluorescence acquisition can be performed using a compatible FAM/SYBR channel.
Can MegaMix Emerald be used for gene-expression analysis?
Answer: Yes. Gene-expression analysis is an explicitly listed application.
Can MegaMix Emerald be used with viral RNA?
Answer: Yes. Viral RNA is one of the RNA template types listed by Microzone.
Can MegaMix Emerald be used for pathogen detection?
Answer: Yes. Pathogen detection is listed as an application. The product remains Research Use Only.
Does MegaMix Emerald contain a hot-start polymerase?
Answer: Yes. It contains chemically modified Hot Start Taq DNA polymerase that is activated during heating to 95ยฐC.
Does MegaMix Emerald include UNG?
Answer: Yes. The current one-step formulation includes thermolabile UNG.
Does MegaMix Emerald contain dUTP?
Answer: Yes. dUTP is included as part of the carryover-contamination-control system.
How does UNG help prevent PCR carryover contamination?
Answer: UNG acts on uracil-containing products from earlier PCR reactions before amplification starts, reducing the chance that carryover amplicons will generate false amplification.
Can MegaMix Emerald be used for melt-curve analysis?
Answer: Yes. Melt-curve analysis is explicitly listed as a use for MegaMix Emerald.
Can MegaMix Emerald be used for High Resolution Melting?
Answer: Yes. Microzone specifically identifies HRM as an application.
Does MegaMix Emerald support fast cycling?
Answer: Yes. Its datasheet states that it is compatible with standard and fast cycling conditions.
Can MegaMix Emerald be used with GC-rich targets?
Answer: Microzone’s datasheet states compatibility with GC-rich and AT-rich templates.
Is MegaMix Emerald inhibitor resistant?
Answer: Microzone describes the product as inhibitor-resistant and identifies direct-to-PCR use with products such as microLYSIS-RNA as an application.
What reaction volume should I use?
Answer: The current datasheet provides a standard 20 ยตl reaction.
Which ROX formulation should I choose?
Answer: MegaMix Emerald is available in No-ROX, Lo-ROX and Hi-ROX formats. Selection should depend on the reference-dye requirements of the qPCR instrument.
Why choose MegaMix Emerald for one-step RT-qPCR?
Answer: Choose MegaMix Emerald when you require dye-based RNA quantification with one-step reverse transcription, Hot Start Taq, microGREEN detection, low-copy-target capability, HRM support and built-in dUTP/UNG carryover control.
ย